USB Electrical Specification

nRF5340 Product Specification

Symbol Description Min. Typ. Max. Units
RUSB,PU,ACTIVE

Value of pull-up on D+, bus active (upstream device transmitting)

1425 2300 3090 Ω
RUSB,PU,IDLE

Value of pull-up on D+, bus idle

900 1200 1575 Ω
tUSB,DETRST

Minimum duration of an SE0 state to be detected as a USB reset condition

10 µs
fUSB,CLK

Frequency of local clock, USB active

48 MHz
fUSB,TOL

Accuracy of local clock, USB active1

±1000 ppm
TUSB,JITTER

Jitter on USB local clock, USB active

±1 ns
1 The local clock can be stopped during USB suspend