| Symbol | Description | Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| tTWIM,SU_DATI |
Input data setup time before positive edge on SCL – all modes |
20 | ns | ||
| tTWIM,HD_DATI |
Input data hold time after negative edge on SCL – 100, 250 and 400 kbps |
0 | ns | ||
| tTWIM,HD_DATO |
Output data hold time after negative edge on SCL – 100, 250 and 400 kbps |
500 | 625 | ns | |
| tTWIM,HD_DATO,1000kbps |
Output data hold time after negative edge on SCL – 1000 kbps |
250 | 315 | ns | |
| tTWIM,HD_STA,100kbps |
TWIM master hold time for START and repeated START condition, 100 kbps |
9900 | ns | ||
| tTWIM,HD_STA,250kbps |
TWIM master hold time for START and repeated START condition, 250 kbps |
3900 | ns | ||
| tTWIM,HD_STA,400kbps |
TWIM master hold time for START and repeated START condition, 400 kbps |
2400 | ns | ||
| tTWIM,HD_STA,1000kbps |
TWIM master hold time for START and repeated START condition, 1000 kbps |
900 | ns | ||
| tTWIM,SU_STO,100kbps |
TWIM master setup time from SCL high to STOP condition, 100 kbps |
5000 | ns | ||
| tTWIM,SU_STO,250kbps |
TWIM master setup time from SCL high to STOP condition, 250 kbps |
2000 | ns | ||
| tTWIM,SU_STO,400kbps |
TWIM master setup time from SCL high to STOP condition, 400 kbps |
1250 | ns | ||
| tTWIM,SU_STO,1000kbps |
TWIM master setup time from SCL high to STOP condition, 1000 kbps |
500 | ns | ||
| tTWIM,BUF,100kbps |
TWIM master bus free time between STOP and START conditions, 100 kbps |
5250 | ns | ||
| tTWIM,BUF,250kbps |
TWIM master bus free time between STOP and START conditions, 250 kbps |
2250 | ns | ||
| tTWIM,BUF,400kbps |
TWIM master bus free time between STOP and START conditions, 400 kbps |
1500 | ns | ||
| tTWIM,BUF,1000kbps |
TWIM master bus free time between STOP and START conditions, 1000 kbps |
750 | ns |