RNG Electrical Specification

nRF5340 Product Specification

Symbol Description Min. Typ. Max. Units
tRNG,START

Time from setting the START task to generation begins. This is a one-time delay on START signal and does not apply between samples.

128 µs
tRNG,RAW

Run time per byte without bias correction. Uniform distribution of 0 and 1 is not guaranteed.

32 µs
tRNG,BC

Run time per byte with bias correction. Uniform distribution of 0 and 1 is guaranteed. Time to generate a byte cannot be guaranteed.

122 µs