VREGH.EXTSILENTEN (Retained)

nRF5340 Product Specification

Address offset: 0xB40

When VREGH is in DC/DC mode, enable VREGH silent mode to supply external components from VDD. Silent mode has lower voltage ripple.

Silent mode is used when DC/DC is enabled, and is ignored in LDO mode. Disabling silent mode reduces current consumption in sleep.

This register is retained.

Bit number 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
ID A
Reset 0x00000001 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1
ID R/W Field Value ID Value Description
A

RW

EXTSILENTEN

Enable silent external DC/DC supply

Disabled

0

Disable

Enabled

1

Enable