Configurable current provided by the current source, excluding variations over temperature and voltage, at 3 V and 25°C. For other voltages and temperatures, the accuracy as specified by ISOURCE,ACC must be added to the min and max values.
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| ISOURCE,A |
Current when register ISOURCE=Ien2mA5 |
1.6 | 2.4 | 3.3 | µA |
| ISOURCE,B |
Current when register ISOURCE=Ien5mA |
3.2 | 4.9 | 6.5 | µA |
| ISOURCE,C |
Current when register ISOURCE=Ien10mA |
6.0 | 9.8 | 13.0 | µA |
| ISOURCE,ACC |
Current source accuracy over temperature and voltage |
±5% | % |