Address offset: 0x570
Automatic or manual control of HFCLK128M/HFCLK64M
The AlwaysRun setting will ensure the clock source is always running, independent of the automatic clock request system.
Note: This setting is activated by triggering the HFCLKSTART task.
| Bit number | 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | A | ||||||||||||||||||||||||||||||||||
| Reset 0x00000000 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
RW |
ALWAYSRUN |
Ensure clock is always running |
||||||||||||||||||||||||||||||||
|
Automatic |
0 |
Use automatic clock control |
|||||||||||||||||||||||||||||||||
|
AlwaysRun |
1 |
Ensure clock is always running |
|||||||||||||||||||||||||||||||||