Address offset: 0x7CC
RT peripheral control
| Bit number | 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | C | B | A | ||||||||||||||||||||||||||||||||
| Reset 0x00000000 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
RW |
CLOCKPOLARITY |
Clock polarity This field is applicable only when OUTMODE.MODE = OutBBufToggleClk |
||||||||||||||||||||||||||||||||
|
Low |
0x0 |
Clock polarity is low |
|||||||||||||||||||||||||||||||||
|
High |
0x1 |
Clock polarity is High |
|||||||||||||||||||||||||||||||||
| B |
RW |
STOPCOUNTERS |
Stop counters CNT0 and CNT1 on OUTB under-run, or on INB Overflow if OUTMODE2 and INMODE2 This feature is used for clock stretching during OUTB under-run |
||||||||||||||||||||||||||||||||
|
NoStop |
0 |
Counters do not stop on OUTB under-run |
|||||||||||||||||||||||||||||||||
|
Stop |
1 |
Counters stop on OUTB under-run Resume the counters when OUTB is written |
|||||||||||||||||||||||||||||||||
| C |
RW |
INSEL |
Input pin selection |
||||||||||||||||||||||||||||||||
|
SamePin |
0x0 |
Sample on same OUT pin |
|||||||||||||||||||||||||||||||||
|
SeparatePin |
0x1 |
Sample on separate pin |
|||||||||||||||||||||||||||||||||