Address offset: 0x510
Number of samples to be taken before REPORTRDY and DBLRDY events can be generated
| Bit number | 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | A | A | A | A | |||||||||||||||||||||||||||||||
| Reset 0x00000000 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
RW |
REPORTPER |
Specifies the number of samples to be accumulated in the ACC register before the REPORTRDY and DBLRDY events can be generated. The report period in [µs] is given as: RPUS = SP * RP, where RPUS is the report period in [µs/report], SP is the sample period in [µs/sample] specified in SAMPLEPER, and RP is the report period in [samples/report] specified in REPORTPER . |
||||||||||||||||||||||||||||||||
|
10Smpl |
0 |
10 samples/report |
|||||||||||||||||||||||||||||||||
|
40Smpl |
1 |
40 samples/report |
|||||||||||||||||||||||||||||||||
|
80Smpl |
2 |
80 samples/report |
|||||||||||||||||||||||||||||||||
|
120Smpl |
3 |
120 samples/report |
|||||||||||||||||||||||||||||||||
|
160Smpl |
4 |
160 samples/report |
|||||||||||||||||||||||||||||||||
|
200Smpl |
5 |
200 samples/report |
|||||||||||||||||||||||||||||||||
|
240Smpl |
6 |
240 samples/report |
|||||||||||||||||||||||||||||||||
|
280Smpl |
7 |
280 samples/report |
|||||||||||||||||||||||||||||||||
|
1Smpl |
8 |
1 sample/report |
|||||||||||||||||||||||||||||||||