Maximum ratings are the extreme limits to which the chip can be exposed for a limited amount of time without permanently damaging it. Exposure to absolute maximum ratings for prolonged periods of time may affect the reliability of the device.
For accelerated lifetime testing (HTOL, etc.), supply voltage should not exceed the recommended operating conditions max value, see Recommended operating conditions.
Table 1. Supply voltage
Parameter
Min.
Max.
Unit
VDD
VDD supply voltage
-0.3
3.9
V
VDDEXT
VDD supply voltage under extended operating
temperature
-0.3
3.7
V
Table 2. I/O pin voltage
Parameter
Min.
Max.
Unit
VI/O, VDD ≤3.6 V
IO voltage
-0.3
VDD + 0.3
V
VI/O, VDD >3.6 V
IO voltage
-0.3
3.9
V
VI/O,EXT, VDDEXT ≤3.4 V
IO voltage under extended operating temperature
-0.3
VDD + 0.3
V
VI/O,EXT, VDDEXT >3.4 V
IO voltage under extended operating temperature
-0.3
3.7
V
Table 3. Radio
Min.
Max.
Unit
RF input level
10
dBm
Table 4. Environmental QFN™ package types
Note
Min.
Max.
Unit
Storage temperature
-40
+125
°C
Reflow soldering temperature
Reflow cycle time is 30 seconds with 3 maximum reflow cycles.
260
°C
Moisture Sensitivity Level (MSL)
2
ESD Human Body Model (HBM)
1
kV
ESD Charged Device Model (CDM)
500
V
Table 5. Environmental CSP package types
Note
Min.
Max.
Unit
Storage temperature
Recommended storage condition is < 40°C and < 90% RH (relative
humidity)
-40
+125
°C
Reflow soldering temperature
Reflow cycle time is 30 seconds with 3 maximum reflow cycles.