| Symbol | Description | Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| tSPIS,VSO |
CLK edge to SDO valid |
37 | ns | ||
| tSPIS,HSO |
SDO hold time after CLK edge |
4 | ns | ||
| tSPIS,SUSI |
SDI to CLK edge setup time |
5 | ns | ||
| tSPIS,HSI |
CLK edge to SDI hold time |
2 | ns |