Power-fail comparator

nRF54LM20A | nRF54LM20B Datasheet

Symbol Description Min. Typ. Max. Units
VPOF

Voltage level warning thresholds (falling supply voltage). Levels are configurable between min. and max. in increments of 100 mV.

1.7 3.2 V
VPOFTOL

Threshold voltage tolerance.

-2 2 %
VPOFHYST

Threshold voltage hysteresis.

40 50 55 mV
VBOR,OFF

Brownout reset voltage range System OFF mode. Brownout only applies to the voltage on VDD.

1.56 1.64 V
VBOR,ON

Brownout reset voltage range System ON mode. Brownout only applies to the voltage on VDD.

1.57 1.64 V