Address offset: 0x100 + (n × 0x4)
Moves the sequencer state according to programmed events.
Might ignore writes when the trace unit is enabled or not idle.
When the sequencer is used, all sequencer state transitions must be programmed with a valid event.
| Bit number | 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | P | O | N | M | L | K | J | I | H | G | F | E | D | C | B | A | |||||||||||||||||||
| Reset 0x00000000 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A-H |
RW |
F[i] (i=0..7) |
Forward field. |
||||||||||||||||||||||||||||||||
|
Disabled |
0 |
The trace event does not affect the sequencer. |
|||||||||||||||||||||||||||||||||
|
Enabled |
1 |
When the event occurs then the sequencer state moves from state n to state n+1. |
|||||||||||||||||||||||||||||||||
| I-P |
RW |
B[i] (i=0..7) |
Backward field. |
||||||||||||||||||||||||||||||||
|
Disabled |
0 |
The trace event does not affect the sequencer. |
|||||||||||||||||||||||||||||||||
|
Enabled |
1 |
When the event occurs then the sequencer state moves from state n+1 to state n. |
|||||||||||||||||||||||||||||||||