RATIO

nRF54LM20A | nRF54LM20B Datasheet

Address offset: 0x520

Selects the decimation ratio between PDM_CLK and output sample rate. When RATIO is selected to be "custom", the decimation rate should be set using the FILTER.CTRL field before setting the RATIO to 7

Change PRESCALER.DIVISOR accordingly.

Bit number 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
ID A A A
Reset 0x00000002 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0
ID R/W Field Value ID Value Description
A

RW

RATIO

Selects the decimation ratio between PDM_CLK and output sample rate

Ratio48

0

Ratio of 48

Ratio50

1

Ratio of 50

Ratio64

2

Ratio of 64

Ratio80

3

Ratio of 80

Ratio96

4

Ratio of 96

Ratio150

5

Ratio of 150

Ratio192

6

Ratio of 192

Custom

7

Custom. The decimation rate can be changed using the FILTER.CTRL[31:25] bits