NORDIC.CNTMODE1

nRF54LM20A | nRF54LM20B Datasheet

Address offset: 0x7D1

CNT1 Mode

Real Time Peripherals VTIM

Bit number 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
ID A A A
Reset 0x00000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
ID R/W Field Value ID Value Description
A

RW

CNTMODE1

CNT1 Mode

STOP

0x0

CNT1 stops at 0

WRAP

0x1

When CNT1 reaches 0 it will continue counting from 0xFFFF

RELOAD

0x2

When CNT1 reches 0 it will continue counting from the value in CNTTOP

TRIGCOMB

0x3

In combine mode mode CNT1 acts as an extension of CNT0 (16 most significant bits of the 32-bit CNT)

TRIGRELOAD

0x4

When CNT1 reaches 0 it is reloaded from CNTTOP and stops. Counting will restart when a VIO event happens

TRIGWRAP

0x5

When CNT1 reaches 0 it wraps to MAX and stops. Counting will restart when a VIO event happens