PROTECT.DOMAIN[n].NIDEN.CTRL

nRF54LM20A | nRF54LM20B Datasheet

Address offset: 0x508 + (n × 0x20)

Control register for non-invasive debug enable for the local debug components within domain n.

Bit number 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
ID D D D D D D D D D D D D D D D D C C C C B A
Reset 0x00000010 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0
ID R/W Field Value ID Value Description
A

RW

VALUE

Set value of niden signal.

Low

0

Signal is logic 0, indicating that non-invasive debug is disabled.

High

1

Signal is logic 1, indicating that non-invasive debug is enabled.

B

W1
W1S

LOCK

Lock this register to prevent changes to the VALUE field until next reset.

Disabled

0

Lock disabled.

Enabled

1

Lock enabled.

C

RW

WRITEPROTECTION

The write protection must be cleared to allow updates to the VALUE field.

The write protection is cleared by writing CLEAR in a separate write operation prior to updating the VALUE and LOCK fields.

The write protection is automatically enabled after the corresponding change to the VALUE field.

Disabled

0x0

Read: Write protection is disabled.

Enabled

0x1

Read: Write protection is enabled.

Clear

0xF

Write: Value to clear write protection.

D

W

KEY

Required write key for upper 16 bits. Must be included in all register write operations.

KEY

0x50FA

Write key value.