Power-fail comparator

nRF54LS05A | nRF54LS05B Preliminary Datasheet

Symbol Description Min. Typ. Max. Units
VPOF

Voltage level warning thresholds (falling supply voltage). Levels are configurable between min. and max. in increments of 100 mV.

1.7 3.2 V
VPOFTOL

Threshold voltage tolerance.

-2 2 %
VPOFHYST

Threshold voltage hysteresis.

40 50 55 mV
VBOR,OFF

Brownout reset voltage range System OFF mode. Brownout only applies to the voltage on VDD.

1.56 1.64 V
VBOR,ON

Brownout reset voltage range System ON mode. Brownout only applies to the voltage on VDD.

1.57 1.64 V