BCHGVTRICKLESEL

nPM1300 Product Specification

Address offset: 0xE

Select trickle charge voltage threshold

Bit number 7 6 5 4 3 2 1 0
ID A
Reset 0x00 0 0 0 0 0 0 0 0
ID R/W Field Value ID Value Description
A

RW

BCHGVTRICKLESEL

Select trickle charge voltage threshold

2V9

0

2.9 V (default)

2V5

1

2.5 V