Electrical specification

nPM1300 Product Specification

Table 7. Electrical specification
Symbol Description Min. Typ. Max. Unit
VBATPOR VBAT power-on reset release voltage 2.75 V
VBATBOR VBAT brownout reset trigger 2.4 V
VBATLOW Minimum VBAT voltage for charging 2.1 V
VRECHARGE Battery voltage level needed to restart charging, % of VTERM 95 %
VTERMACC

Accuracy of termination voltage

VBUS = 5.0 V

TJ > 0°C

-1 +1 %
VTERM Range of termination voltage

3.50 to 3.65

4.00 to 4.45

V
VTERMR Range of termination voltage for NTCHOT > T > NTCWARM

3.50 to 3.65

4.00 to 4.45

V
VTERM_STEP Termination voltage step size 50 mV
ICHG Range of constant currents 32 to 800 mA
ICHGACC Constant current accuracy -10 10 %
ICHGSTEP Charging current step 2 mA
ITRICKLE Trickle charging current, % of ICHG 10 %
ICOOL Reduced charging current, % of ICHG 50 %
ITERM Termination current, % of ICHG

10

20

%
VTRICKLE_FAST Default threshold where trickle charging stops and constant current charging starts 2.9 V
VCHDROPOUT Charger dropout voltage 60 mV
IBATLIMLOW Discharging battery current limit on low setting 2001 mA
IBATLIMHIGH Discharging battery current limit on high setting 11 A
RONCHARGER Resistance between pins VBAT and VSYS 160 mΩ
VSYSBELOW_VBAT VSYS below VBAT comparator threshold, VBAT - VSYS, VSYS falling 75 mV
tSWITCH

Dynamic power-path switching time

(2.8 V < VBAT < 5.5 V)

161 μs
TACC Temperature accuracy when using suggested NTC ±2 °C
TCHGSTOP Die temperature where charging stops (default) 110 °C
TCHGRESUME Die temperature where charging resumes (default) 100 °C
tOUTTRICKLE Trickle charging timeout 10 min
tOUTCHARGE Charging timeout which covers constant current and constant voltage 7 h

1 Validated through simulation.