Two load switches are available for use as switches or LDO regulators (LDO). They have dedicated input pins where voltage cannot exceed VSYS. The input voltage can be equal to VOUT1, VOUT2, or any voltage up to the VSYS voltage.
The mode is selected using registers LDSW[n]LDOSEL.
The load switches (and LDOs) are OFF by default and can be controlled through control registers or GPIO pins using the following bits.
- Control register bits for each load switch or LDO:
- GPIO[n], once configured by host software:
When a GPIO is used to control LOADSW/LDO, it uses edges. When the GPIO toggles from LOW to HIGH, LOADSW/LDO turns ON (switch conducting). When the GPIO toggles from HIGH to LOW, LOADSW/LDO turns OFF.
Each load switch or LDO can be assigned to a separate GPIO, or a single GPIO can control both switches or LDOs.
A pull-down resistor RLSPD on the LSOUT[n] pin is enabled in a register bit for LOADSW/LDO. See register LDSW.LDSWCONFIG.
Load switch mode
Soft start is enabled by default. This ensures that the current to LSOUT[n] is limited for tSS. Once soft start is complete, there will be no current limiting provided by the load switch. Current limiting is only available from the power source connected to LSIN[n].
The soft start current limit for a load switch can be set in register LDSW.LDSWCONFIG.
LDO mode
The load switches can be independently configured as LDOs. The LDO output voltage is configurable in registers LDSW[n]VOUTSEL.
The LDO can be supplied from VOUT1, VOUT2 or VSYS, but must comply with VINLDO.
Electrical specification
| Symbol | Description | Min. | Typ. | Max. | Unit |
|---|---|---|---|---|---|
| RDSONLS |
Switch on-resistance LSIN = 3.3 V |
200 | mΩ | ||
| ILS |
Current LSOUT ≥ 1.2 V |
100 | mA | ||
| tSS |
Soft start time Soft start current limit = 25 mA, 10 µF, 0 V to 5 V |
1.8 | ms | ||
| RLSPD | Pull-down resistor (active discharge) at LSOUT | 2 | kΩ | ||
| VINLS | Input voltage range | 1.0 | VSYS | V | |
| IQLS | Additional quiescent current from VBAT when load switch is enabled (VBAT = 3.8 V, VINLS = VSYS, ILOAD = 0, VBUS disconnected, both BUCKs running in Hysteretic mode) | 60 | nA |
| Symbol | Description | Min. | Typ. | Max. | Unit |
|---|---|---|---|---|---|
| IOUTLDO | Output current VOUT > 1.2 V | 50 | mA | ||
| IOUTLDO | Output current VOUT < 1.2 V | 10 | mA | ||
| VINLDO | Input voltage range | 2.6 | VSYS | V | |
| VOUTLDO | Minimum setting output voltage | 1.0 | V | ||
| VOUTLDO | Maximum setting output voltage | 3.3 | V | ||
| VOUTLDO_STEP | Output voltage step size | 100 | mV | ||
| VOUTACC | DC output voltage
accuracy (VINLDO = 3.8 V to 5.5 V, ILOAD = 1 mA) |
±3 | % | ||
| LINEREG_LDO | DC line regulation
(VOUTLDO = 1.0 V, VINLDO = 3 V to 5.5 V, ILOAD = 1 mA) |
2 | mV/V | ||
| DC line regulation
(VOUTLDO = 1.8 V, VINLDO = 3 V to 5.5 V, ILOAD = 1 mA) |
4 | mV/V | |||
| DC line regulation
(VOUTLDO = 3.3 V, VINLDO = 3.7 V to 5.5 V, ILOAD = 1 mA) |
11 | mV/V | |||
| LOADREG_LDO | DC load
regulation (VOUTLDO = 1 V to 1.2 V, VINLDO = 3.8 V, ILOAD = 50 μA to 10 mA) |
0.4 | mV/mA | ||
| DC load
regulation (VOUTLDO = 1.8 V to 3.3 V, VINLDO = 3.8 V, ILOAD = 50 μA to 50 mA) |
0.25 | mV/mA | |||
| PSRR | Power supply rejection
ratio (VOUTLDO = 3 V, VINLDO = 3.8 V, ILOAD = 20 mA, f = 1 kHz) |
50 | dB | ||
| VRIPPLE | Output voltage ripple in ULP
mode (VBUS disconnected, both BUCKs running in Hysteretic mode, VOUTLDO = 1.8 V, VINLDO = 3.8 V, ILOAD = 1 mA) |
17 | mVp-p | ||
| Output voltage ripple in ULP
mode (VBUS disconnected, both BUCKs running in Hysteretic mode, VOUTLDO = 3.3 V, VINLDO = 3.8 V, ILOAD = 1 mA) |
35 | mVp-p | |||
| LDODROPOUT | Dropout
voltage VOUTLDO = 3.3 V, ILOAD = 50 mA |
25 | mV | ||
| IQLDO | Additional quiescent current from VBAT when LDO is enabled (VBAT = 3.8 V, VINLDO = VSYS, ILOAD = 0, VBUS disconnected, both BUCKs running in Hysteretic mode) | 500 | nA | ||
| Additional quiescent current from VBAT when LDO is enabled (VBAT = 3.8 V, VINLDO = VSYS, ILOAD = 0, VBUS disconnected, both BUCKs running in PWM mode) | 10 | μA |
Electrical characteristics
The following graphs show typical electrical characteristics for LOADSW.
The following graphs show electrical characteristics for LDO.
Registers
Instances
| Instance | Base address | Description |
|---|---|---|
| LDSW | 0x00000800 |
LOADSW registers LDSW register map |
Register overview
| Register | Offset | Description |
|---|---|---|
| TASKLDSW1SET | 0x0 |
Enable LDSW1 |
| TASKLDSW1CLR | 0x1 |
Disable LDSW1 |
| TASKLDSW2SET | 0x2 |
Enable LDSW2 |
| TASKLDSW2CLR | 0x3 |
Disable LDSW2 |
| LDSWSTATUS | 0x4 |
Load switch and LDO status |
| LDSW1GPISEL | 0x5 |
LDSW1 GPIO control select |
| LDSW2GPISEL | 0x6 |
LDSW2 GPIO control select |
| LDSWCONFIG | 0x7 |
Load switch or LDO configuration |
| LDSW1LDOSEL | 0x8 |
Select LDSW1 mode |
| LDSW2LDOSEL | 0x9 |
Select LDSW2 mode |
| LDSW1VOUTSEL | 0xC |
LDO1 programmable output voltage |
| LDSW2VOUTSEL | 0xD |
LDO2 programmable output voltage |
TASKLDSW1SET
Address offset: 0x0
Enable LDSW1
| Bit number | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | A | ||||||||||||||||||||||||||||||||||
| Reset 0x00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
W |
TASKLDSW1SET |
Set LDSW1 enable |
||||||||||||||||||||||||||||||||
|
NOEFFECT |
0 |
No effect |
|||||||||||||||||||||||||||||||||
|
SET |
1 |
Set enable |
|||||||||||||||||||||||||||||||||
TASKLDSW1CLR
Address offset: 0x1
Disable LDSW1
| Bit number | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | A | ||||||||||||||||||||||||||||||||||
| Reset 0x00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
W |
TASKLDSW1CLR |
Clear LDSW1 enable |
||||||||||||||||||||||||||||||||
|
NOEFFECT |
0 |
No effect |
|||||||||||||||||||||||||||||||||
|
CLR |
1 |
Clear enable |
|||||||||||||||||||||||||||||||||
TASKLDSW2SET
Address offset: 0x2
Enable LDSW2
| Bit number | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | A | ||||||||||||||||||||||||||||||||||
| Reset 0x00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
W |
TASKLDSW2SET |
Set LDSW2 enable |
||||||||||||||||||||||||||||||||
|
NOEFFECT |
0 |
No effect |
|||||||||||||||||||||||||||||||||
|
SET |
1 |
Set enable |
|||||||||||||||||||||||||||||||||
TASKLDSW2CLR
Address offset: 0x3
Disable LDSW2
| Bit number | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | A | ||||||||||||||||||||||||||||||||||
| Reset 0x00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
W |
TASKLDSW2CLR |
Clear LDSW2 enable |
||||||||||||||||||||||||||||||||
|
NOEFFECT |
0 |
No effect |
|||||||||||||||||||||||||||||||||
|
CLR |
1 |
Clear enable |
|||||||||||||||||||||||||||||||||
LDSWSTATUS
Address offset: 0x4
Load switch and LDO status
| Bit number | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | E | D | C | B | A | ||||||||||||||||||||||||||||||
| Reset 0x00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
R |
LDSW1PWRUPLDSW |
Load switch 1 status |
||||||||||||||||||||||||||||||||
|
OFF |
0 |
OFF |
|||||||||||||||||||||||||||||||||
|
ON |
1 |
ON |
|||||||||||||||||||||||||||||||||
| B |
R |
LDSW1PWRUPLDO |
LDO1 status |
||||||||||||||||||||||||||||||||
|
OFF |
0 |
OFF |
|||||||||||||||||||||||||||||||||
|
ON |
1 |
ON |
|||||||||||||||||||||||||||||||||
| C |
R |
LDSW2PWRUPLDSW |
Load switch 2 status |
||||||||||||||||||||||||||||||||
|
OFF |
0 |
OFF |
|||||||||||||||||||||||||||||||||
|
ON |
1 |
ON |
|||||||||||||||||||||||||||||||||
| D |
R |
LDSW2PWRUPLDO |
LDO2 status |
||||||||||||||||||||||||||||||||
|
OFF |
0 |
OFF |
|||||||||||||||||||||||||||||||||
|
ON |
1 |
ON |
|||||||||||||||||||||||||||||||||
| E |
R |
LDSWENABLE |
LDSW1 or LDSW2 in use |
||||||||||||||||||||||||||||||||
|
OFF |
0 |
OFF |
|||||||||||||||||||||||||||||||||
|
ON |
1 |
ON |
|||||||||||||||||||||||||||||||||
LDSW1GPISEL
Address offset: 0x5
LDSW1 GPIO control select
| Bit number | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | B | A | A | A | |||||||||||||||||||||||||||||||
| Reset 0x00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
RW |
LDSW1GPISEL |
Select which GPIO controls LDSW1 |
||||||||||||||||||||||||||||||||
|
NOTUSED1 |
0 |
No GPIO selected |
|||||||||||||||||||||||||||||||||
|
GPIO0 |
1 |
GPIO 0 selected |
|||||||||||||||||||||||||||||||||
|
GPIO1 |
2 |
GPIO 1 selected |
|||||||||||||||||||||||||||||||||
|
GPIO2 |
3 |
GPIO 2 selected |
|||||||||||||||||||||||||||||||||
|
GPIO3 |
4 |
GPIO 3 selected |
|||||||||||||||||||||||||||||||||
|
GPIO4 |
5 |
GPIO 4 selected |
|||||||||||||||||||||||||||||||||
|
NOTUSED2 |
6 |
No GPIO selected |
|||||||||||||||||||||||||||||||||
|
NOTUSED3 |
7 |
No GPIO selected |
|||||||||||||||||||||||||||||||||
| B |
RW |
LDSW1GPIINV |
Invert the sense of the selected GPIO |
||||||||||||||||||||||||||||||||
|
NORMAL |
0 |
Not inverted |
|||||||||||||||||||||||||||||||||
|
INVERTED |
1 |
Inverted |
|||||||||||||||||||||||||||||||||
LDSW2GPISEL
Address offset: 0x6
LDSW2 GPIO control select
| Bit number | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | B | A | A | A | |||||||||||||||||||||||||||||||
| Reset 0x00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
RW |
LDSW2GPISEL |
Select which GPIO controls LDSW2 |
||||||||||||||||||||||||||||||||
|
NOTUSED1 |
0 |
No GPIO selected |
|||||||||||||||||||||||||||||||||
|
GPIO0 |
1 |
GPIO 0 selected |
|||||||||||||||||||||||||||||||||
|
GPIO1 |
2 |
GPIO 1 selected |
|||||||||||||||||||||||||||||||||
|
GPIO2 |
3 |
GPIO 2 selected |
|||||||||||||||||||||||||||||||||
|
GPIO3 |
4 |
GPIO 3 selected |
|||||||||||||||||||||||||||||||||
|
GPIO4 |
5 |
GPIO 4 selected |
|||||||||||||||||||||||||||||||||
|
NOTUSED2 |
6 |
No GPIO selected |
|||||||||||||||||||||||||||||||||
|
NOTUSED3 |
7 |
No GPIO selected |
|||||||||||||||||||||||||||||||||
| B |
RW |
LDSW2GPIINV |
Invert the sense of the selected GPIO |
||||||||||||||||||||||||||||||||
|
NORMAL |
0 |
Not inverted |
|||||||||||||||||||||||||||||||||
|
INVERTED |
1 |
Inverted |
|||||||||||||||||||||||||||||||||
LDSWCONFIG
Address offset: 0x7
Load switch or LDO configuration
| Bit number | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | F | E | D | D | C | C | B | A | |||||||||||||||||||||||||||
| Reset 0x00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
RW |
LDSW1SOFTSTARTDISABLE |
LDSW1 soft start disable |
||||||||||||||||||||||||||||||||
|
NOEFFECT |
0 |
No effect |
|||||||||||||||||||||||||||||||||
|
NOSOFTSTART |
1 |
Soft start disabled |
|||||||||||||||||||||||||||||||||
| B |
RW |
LDSW2SOFTSTARTDISABLE |
LDSW2 soft start disable |
||||||||||||||||||||||||||||||||
|
NOEFFECT |
0 |
No effect |
|||||||||||||||||||||||||||||||||
|
NOSOFTSTART |
1 |
Soft start disabled |
|||||||||||||||||||||||||||||||||
| C |
RW |
LDSW1SOFTSTARTSEL |
Select soft start level for LDSW1 |
||||||||||||||||||||||||||||||||
|
25MA |
0 |
25 mA |
|||||||||||||||||||||||||||||||||
|
50MA |
1 |
50 mA |
|||||||||||||||||||||||||||||||||
|
75MA |
2 |
75 mA |
|||||||||||||||||||||||||||||||||
|
100MA |
3 |
100 mA |
|||||||||||||||||||||||||||||||||
| D |
RW |
LDSW2SOFTSTARTSEL |
Select soft start level for LDSW2 |
||||||||||||||||||||||||||||||||
|
25MA |
0 |
25 mA |
|||||||||||||||||||||||||||||||||
|
50MA |
1 |
50 mA |
|||||||||||||||||||||||||||||||||
|
75MA |
2 |
75 mA |
|||||||||||||||||||||||||||||||||
|
100MA |
3 |
100 mA |
|||||||||||||||||||||||||||||||||
| E |
RW |
LDSW1ACTIVEDISCHARGE |
LDSW1 active discharge enable |
||||||||||||||||||||||||||||||||
|
NODISCHARGE |
0 |
No discharge |
|||||||||||||||||||||||||||||||||
|
ACTIVE |
1 |
Active discharge enabled |
|||||||||||||||||||||||||||||||||
| F |
RW |
LDSW2ACTIVEDISCHARGE |
LDSW2 active discharge enable |
||||||||||||||||||||||||||||||||
|
NODISCHARGE |
0 |
No discharge |
|||||||||||||||||||||||||||||||||
|
ACTIVE |
1 |
Active discharge enabled |
|||||||||||||||||||||||||||||||||
LDSW1LDOSEL
Address offset: 0x8
Select LDSW1 mode
| Bit number | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | A | ||||||||||||||||||||||||||||||||||
| Reset 0x00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
RW |
LDSW1LDOSEL |
Select Load switch or LDO |
||||||||||||||||||||||||||||||||
|
LDSW |
0 |
Load switch |
|||||||||||||||||||||||||||||||||
|
LDO |
1 |
LDO |
|||||||||||||||||||||||||||||||||
LDSW2LDOSEL
Address offset: 0x9
Select LDSW2 mode
| Bit number | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | A | ||||||||||||||||||||||||||||||||||
| Reset 0x00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
RW |
LDSW2LDOSEL |
Select Load switch or LDO |
||||||||||||||||||||||||||||||||
|
LDSW |
0 |
Load switch |
|||||||||||||||||||||||||||||||||
|
LDO |
1 |
LDO |
|||||||||||||||||||||||||||||||||
LDSW1VOUTSEL
Address offset: 0xC
LDO1 programmable output voltage
| Bit number | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | A | A | A | A | A | ||||||||||||||||||||||||||||||
| Reset 0x00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
RW |
LDSW1VOUTSEL |
LDO1 programmable output voltage |
||||||||||||||||||||||||||||||||
|
1V |
0 |
1.0 V |
|||||||||||||||||||||||||||||||||
|
1V1 |
1 |
1.1 V |
|||||||||||||||||||||||||||||||||
|
1V2 |
2 |
1.2 V |
|||||||||||||||||||||||||||||||||
|
1V3 |
3 |
1.3 V |
|||||||||||||||||||||||||||||||||
|
1V4 |
4 |
1.4 V |
|||||||||||||||||||||||||||||||||
|
1V5 |
5 |
1.5 V |
|||||||||||||||||||||||||||||||||
|
1V6 |
6 |
1.6 V |
|||||||||||||||||||||||||||||||||
|
1V7 |
7 |
1.7 V |
|||||||||||||||||||||||||||||||||
|
1V8 |
8 |
1.8 V |
|||||||||||||||||||||||||||||||||
|
1V9 |
9 |
1.9 V |
|||||||||||||||||||||||||||||||||
|
2V |
10 |
2.0 V |
|||||||||||||||||||||||||||||||||
|
2V1 |
11 |
2.1 V |
|||||||||||||||||||||||||||||||||
|
2V2 |
12 |
2.2 V |
|||||||||||||||||||||||||||||||||
|
2V3 |
13 |
2.3 V |
|||||||||||||||||||||||||||||||||
|
2V4 |
14 |
2.4 V |
|||||||||||||||||||||||||||||||||
|
2V5 |
15 |
2.5 V |
|||||||||||||||||||||||||||||||||
|
2V6 |
16 |
2.6 V |
|||||||||||||||||||||||||||||||||
|
2V7 |
17 |
2.7 V |
|||||||||||||||||||||||||||||||||
|
2V8 |
18 |
2.8 V |
|||||||||||||||||||||||||||||||||
|
2V9 |
19 |
2.9 V |
|||||||||||||||||||||||||||||||||
|
3V |
20 |
3.0 V |
|||||||||||||||||||||||||||||||||
|
3V1 |
21 |
3.1 V |
|||||||||||||||||||||||||||||||||
|
3V2 |
22 |
3.2 V |
|||||||||||||||||||||||||||||||||
|
3V3 |
23 |
3.3 V |
|||||||||||||||||||||||||||||||||
LDSW2VOUTSEL
Address offset: 0xD
LDO2 programmable output voltage
| Bit number | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID | A | A | A | A | A | ||||||||||||||||||||||||||||||
| Reset 0x00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| ID | R/W | Field | Value ID | Value | Description | ||||||||||||||||||||||||||||||
| A |
RW |
LDSW2VOUTSEL |
LDO2 programmable output voltage |
||||||||||||||||||||||||||||||||
|
1V |
0 |
1.0 V |
|||||||||||||||||||||||||||||||||
|
1V1 |
1 |
1.1 V |
|||||||||||||||||||||||||||||||||
|
1V2 |
2 |
1.2 V |
|||||||||||||||||||||||||||||||||
|
1V3 |
3 |
1.3 V |
|||||||||||||||||||||||||||||||||
|
1V4 |
4 |
1.4 V |
|||||||||||||||||||||||||||||||||
|
1V5 |
5 |
1.5 V |
|||||||||||||||||||||||||||||||||
|
1V6 |
6 |
1.6 V |
|||||||||||||||||||||||||||||||||
|
1V7 |
7 |
1.7 V |
|||||||||||||||||||||||||||||||||
|
1V8 |
8 |
1.8 V |
|||||||||||||||||||||||||||||||||
|
1V9 |
9 |
1.9 V |
|||||||||||||||||||||||||||||||||
|
2V |
10 |
2.0 V |
|||||||||||||||||||||||||||||||||
|
2V1 |
11 |
2.1 V |
|||||||||||||||||||||||||||||||||
|
2V2 |
12 |
2.2 V |
|||||||||||||||||||||||||||||||||
|
2V3 |
13 |
2.3 V |
|||||||||||||||||||||||||||||||||
|
2V4 |
14 |
2.4 V |
|||||||||||||||||||||||||||||||||
|
2V5 |
15 |
2.5 V |
|||||||||||||||||||||||||||||||||
|
2V6 |
16 |
2.6 V |
|||||||||||||||||||||||||||||||||
|
2V7 |
17 |
2.7 V |
|||||||||||||||||||||||||||||||||
|
2V8 |
18 |
2.8 V |
|||||||||||||||||||||||||||||||||
|
2V9 |
19 |
2.9 V |
|||||||||||||||||||||||||||||||||
|
3V |
20 |
3.0 V |
|||||||||||||||||||||||||||||||||
|
3V1 |
21 |
3.1 V |
|||||||||||||||||||||||||||||||||
|
3V2 |
22 |
3.2 V |
|||||||||||||||||||||||||||||||||
|
3V3 |
23 |
3.3 V |
|||||||||||||||||||||||||||||||||