The set command reads modem parameters.
Syntax:
%XMONITOR
Response
syntax:v1.0.xv1.1.x
%XMONITOR: <reg_status>,[<full_name>,<short_name>,<plmn>,<tac>,<AcT>,<band>,<cell_id>,
<phys_cell_id>,<EARFCN>,<rsrp>,<snr>,<NW-provided_eDRX_value>,<Active-Time>,<Periodic-TAU-ext>]
Response
syntax:v1.2.xv1.3.x
%XMONITOR: <reg_status>,[<full_name>,<short_name>,<plmn>,<tac>,<AcT>,<band>,<cell_id>,
<phys_cell_id>,<EARFCN>,<rsrp>,<snr>,<NW-provided_eDRX_value>,<Active-Time>,<Periodic-TAU-ext>,<Periodic-TAU>]
The response parameters and their defined values are the following:
- <reg_status>
- 0 – Not registered. User Equipment (UE) is not currently searching for an
operator to register to.
- 1 – Registered, home network.
- 2 – Not registered, but UE is currently trying to attach or searching an operator to
register to.
- 3 – Registration denied.
- 4 – Unknown (for example, out of Evolved Terrestrial Radio Access Network (E-UTRAN) coverage).
- 5 – Registered, roaming.
- 90 – Not registered due to Universal Integrated Circuit Card (UICC) failure.
-
Note: The optional part is included in the response only when
<reg_status> is 1 or 5. Some parameters might not be present
in specific circumstances. For example, <phys_cell_id>,
<EARFCN>, <rsrp>, and
<snr> are not available when the device is not camped on a
cell.
- <full_name>
- String in alphanumeric format. Operator name.
- <short_name>
- String in alphanumeric format. Operator name.
- <plmn>
- String of digits. Mobile Country Code (MCC) and Mobile Network Code (MNC) values.
- <tac>
- String in hexadecimal format. 2-byte Tracking Area Code (TAC).
- <AcT>
- 7 – E-UTRAN.
- 9 – E-UTRAN NB-S1.
- <band>
- Integer, 1−85. See 3GPP 36.101. The value is 0 when current band information is not
available.
- <cell_id>
- String in hexadecimal format. 4-byte E-UTRAN cell ID.
- <phys_cell_id>
- Integer. Physical cell ID.
- <EARFCN>
- Integer. E-UTRA Absolute Radio Frequency Channel Number (EARFCN) for a given cell where EARFCN is as
defined in 3GPP TS 36.101.
- <rsrp>
- Integer. Reported RSRP value.
- 0 – When measured RSRP < −140 dBm.
- 1 – When −140 dBm ≤ measured RSRP < −139 dBm.
- 2 – When −139 dBm ≤ measured RSRP < −138 dBm.
- ...
- 95 – When −46 dBm ≤ measured RSRP < −45 dBm.
- 96 – When −45 dBm ≤ measured RSRP < −44 dBm.
- 97 – When −44 dBm ≤ measured RSRP.
- 255 – Not known or not detectable.
- The lower dB boundary of this range can be determined using the reported RSRP value
and the following formula: reported RSRP value–141=dBm. For example, 95–141=–46 dBm.
Thus, the range is –46 dBm ≤ measured RSRP < –45 dBm.
- <snr>
- Reported SNR value.
- 0 – When measured SNR < −24 dB.
- 1 – When −24 dB ≤ measured SNR < −23 dB.
- 2 – When −23 dB ≤ measured SNR < −22 dB.
- ...
- 47 – When 22 dB ≤ measured SNR < 23 dB.
- 48 – When 23 dB ≤ measured SNR < 24 dB.
- 49 – When 24 dB ≤ measured SNR.
- 127 – Not known or not detectable.
- The lower dB boundary of this range can be determined using the reported SNR value and
the following formula: reported value of SNR–25=dB. For example, 1–25=–24 dB. Thus, the
range is –24 dB ≤ measured SNR < –23 dB. Also, 47–25=22 dB. Thus, the range is 22 dB
≤ measured SNR < 23 dB.
- <NW-provided_eDRX_value>
- String. Half a byte in 4-bit format.
- A configuration value that the network provides for the eDRX period. The value in this
parameter does not necessarily indicate that eDRX is in use by the current cell to which
the UE is registered. The use of eDRX can be dynamically monitored with the unsolicited
notification +CEDRXP and its <ActT-type>
parameter.
- The Extended Discontinuous Reception (eDRX) value refers to bit 4 to 1 of octet 3 of the
Extended DRX parameters information element (see 3GPP TS 24.008, subclause
10.5.5.32).
- Bit
- 4 3 2 1 – E-UTRAN e-I-DRX cycle length duration.
- 0 0 0 0 – 5.12 s2.
- 0 0 0 1 – 10.24 s2.
- 0 0 1 0 – 20.48 s.
- 0 0 1 1 – 40.96 s.
- 0 1 0 0 – 61.44 s3.
- 0 1 0 1 – 81.92 s.
- 0 1 1 0 – 102.4 s3.
- 0 1 1 1 – 122.88 s3.
- 1 0 0 0 – 143.36 s3.
- 1 0 0 1 – 163.84 s.
- 1 0 1 0 – 327.68 s.
- 1 0 1 1 – 655,36 s.
- 1 1 0 0 – 1,310.72 s.
- 1 1 0 1 – 2,621.44 s.
- 1 1 1 0 – 5,242.88 s4.
- 1 1 1 1 – 10,485.76 s4.
- <Active-Time>
- String. 1 byte in 8-bit format.
- Indicates the Active Time value (T3324) allocated to the device in E-UTRAN. For the
coding and value range, see the GPRS Timer 2 IE in 3GPP TS 24.008 Table
10.5.163/3GPP TS 24.008.
- The device can enter Power Saving Mode (PSM) state in LTE idle mode when the
<Active-Time> parameter has a valid value where at least one
of bits 6–8 is set to 0. The length of PSM sleep is the value that
remains from the value configured for periodic TAU after active time has elapsed, which
is T3324 subtracted from T3412.
- GPRS Timer 2 value (octet 3).
- Bits 5 to 1 represent the binary coded timer value.
- Bits 8 to 6 define the timer value unit for the GPRS timer as follows:
- Bits
- 8 7 6
- 0 0 0 – Value is incremented in multiples of 2 s
- 0 0 1 – Value is incremented in multiples of 1 min
- 0 1 0 – Value is incremented in multiples of 6 min
- 1 1 1 – Value indicates that the timer is deactivated
- <Periodic-TAU-ext>
- String. 1 byte in 8-bit format.
- Indicates the extended periodic TAU value (T3412_EXT extended value) allocated to the
device in E-UTRAN. For the coding and value range, see the GPRS Timer 3 IE in 3GPP
TS 24.008 Table 10.5.163a/3GPP TS 24.008.
- GPRS Timer 3 value (octet 3).
- Bits 5 to 1 represent the binary coded timer value.
- Bits 8 to 6 define the timer value unit for the GPRS timer as follows:
- Bits
- 8 7 6
- 0 0 0 – Value is incremented in multiples of 10 min.
- 0 0 1 – Value is incremented in multiples of 1 h.
- 0 1 0 – Value is incremented in multiples of 10 h.
- 0 1 1 – Value is incremented in multiples of 2 s.
- 1 0 0 – Value is incremented in multiples of 30 s.
- 1 0 1 – Value is incremented in multiples of 1 min.
- 1 1 0 – Value is incremented in multiples of 320 h.
- 1 1 1 – Value indicates that the timer is deactivated.
- <Periodic-TAU>v1.2.xv1.3.x
- String. 1 byte in 8-bit format.
- Indicates the periodic TAU value (T3412) allocated to the device in E-UTRAN. For the
coding and value range, see the GPRS Timer IE in 3GPP TS 24.008 Table
10.5.172/3GPP TS 24.008.
- Timer value (octet 2).
- Bits 5 to 1 represent the binary coded timer value.
- Bits 8 to 6 define the timer value unit for the GPRS timer as follows:
- Bits
- 8 7 6
- 0 0 0 – Value is incremented in multiples of 2 s.
- 0 0 1 – Value is incremented in multiples of 1 min.
- 0 1 0 – Value is incremented in multiples of 6 min.
- 1 1 1 – Value indicates that the timer is deactivated.
The following command example reads modem parameters:v1.0.xv1.1.x
AT%XMONITOR
%XMONITOR: 1,"EDAV","EDAV","26295","00B7",7,4,"00011B07",7,2300,63,39,"",
"11100000","11100000"
OK
The following command example reads modem
parameters:v1.2.xv1.3.x
AT%XMONITOR
%XMONITOR: 1,"EDAV","EDAV","26295","00B7",7,4,"00011B07",7,2300,63,39,"",
"11100000","11100000","11100000"