The following table is a complete overview of the solder bridges on the nRF9151 SMA DK.

Table 1. Solder bridge configuration
Solder bridge Default Function
SB3 Closed Cut to disconnect RXD of UART1 from nRF9151 SiP
SB4 Closed Cut to disconnect TXD of UART1 from nRF9151 SiP
SB5 Closed Cut to disconnect RTS of UART1 from nRF9151 SiP
SB6 Closed Cut to disconnect CTS of UART1 from nRF9151 SiP
SB7 Closed Cut to disconnect RXD of UART2 from nRF9151 SiP
SB8 Closed Cut to disconnect TXD of UART2 from nRF9151 SiP
SB9 Closed Cut to disconnect RTS of UART2 from nRF9151 SiP
SB10 Closed Cut to disconnect CTS of UART2 from nRF9151 SiP
SB12 Open Short to permanently connect SIM VDD, bypass SIM current measurement connector
SB13 Open Close to reroute SIMDATA to pin 2 of MFF2
SB14 Closed Cut to disconnect SIMDATA from pin 3 of MFF2
SB15 Open Short to connect external board power to VIO_REF
SB16 Open Short to use VDD rail as power source for the external board
SB17 Closed Cut to disable P20 pin 3 (VTG) as select pin
SB18 Closed Cut to disconnect P5 pin 6 from shield detect
SB19 Open Short to connect P5 pin 6 to GND
SB20 Open Close to connect VDD to the UART1 connector
SB21 Closed Cut to disconnect RESET from P7
SB22 Open Short to connect P0.21 to RESET on P1
SB23 Closed Cut to disconnect P0.21 from RESET on P7
SB24 Closed Cut to disconnect RESET from AREF on P4 and P10
SB25 Closed Cut to disconnect RESET pins of P11 and P7
SB26 Open Short to connect RESET pins of P11 and P5
SB27 Open Short to connect RESET pins of P1 and P7
SB28 Closed Cut to disconnect RESET pins of P1 and P5
SB29 Open Short to permanently enable USB_DETECT signal
SB30 Closed Cut to disconnect VIO supply to P1 and P7
SB31 Closed Cut to enable nRF9151 VDD_GPIO current measurement on P20
SB32 Closed Cut to disconnect interface MCU power supply
SB33 Closed Cut to disconnect nPM1300 output from VDD
SB34 Open Short to permanently connect VDD_nRF and VDD_nRF', bypass current measurement connector
SB35 Closed Cut to disconnect 5V on P1 and P7 from VDD_5V