[36] CHARGER: CHARGER does not charge for certain types of PCM

nPM1300 Engineering C Errata

This anomaly applies to Engineering C, build codes QEAA-BA0, CAAA-BA0, QEAA-BC0.

Symptoms

Battery does not charge after an overdischarge event.

Conditions

Battery pack's overcurrent protection is active and requires a voltage higher than VTERM * 0.95 to deactivate.

Consequences

Charging does not start.

Workaround

Set VTERM so that VTERM * 0.95 is greater than the battery’s overdischarge PCM release voltage. Once the battery has deactivated the overdischarge protection, set VTERM back to the battery termination voltage.