This anomaly applies to Engineering C, build codes QEAA-BA0, CAAA-BA0, QEAA-BC0.
Symptoms
BUCK output voltage exhibits a negative transient.
Conditions
One or both of the following conditions are present:
- Data is transmitted on TWI lines.
- BUCK is transitioning mode from PWM to Hysteretic when BUCKS are in auto mode and nPM1300 supplied only by VBAT. Resulting transient duration depends on load. Lower loads exhibit a longer transient.
Consequences
BUCK output voltage transient exceeds specification of ±5%. BUCK output voltage reduces by approximately 8%.
Workaround
If data is being transmitted on TWI lines, avoid TWI activity when output voltage accuracy is critical. Reducing driver strength of TWI reduces inaccuracy.
If BUCK is transitioning mode from PWM to Hysteretic when BUCKS are in auto mode and nPM1300 supplied only by VBAT, use forced PWM or Hysteric mode when output voltage accuracy is critical.