This anomaly applies to IC Rev. Engineering D, build codes CLAA-DA0, QKAA-DB0.
It was inherited from the previous IC revision Engineering A.
Domains
Application
Symptoms
Reset of the operating state after FIELDLOST event. In some cases, communication with the peer device is not possible.
Conditions
Especially with stronger field strengths.
Consequences
Restart of transfer is required.
Workaround
On FIELDDETECTED event, wait 1 ms using timer before starting NFC communication with NRF_NFCT->TASKS_ACTIVATE.
This workaround is included in nrfx v2.0.0 and later.