Solder bridge configuration

nRF54LM20 DK Hardware

The nRF54LM20 DK has a range of solder bridges for enabling or disabling functionality on the nRF54LM20 DK.

The following table is an overview of the solder bridges on the nRF54LM20 DK.

Table 1. Solder bridge configuration
Solder bridge Default Function
SB1 Closed Cut to disconnect the 32.768 kHz from P1.20.
SB2 Closed Cut to disconnect the 32.768 kHz from P1.21.
SB3 Open Short to enable P1.20 as GPIO.
SB4 Open Short to enable P1.21 as GPIO.
SB5 Closed Cut to disconnect the IO3 signal for external flash from the nRF54LM20B SoC.
SB6 Closed Cut to disconnect VBUS:nRF from the power switch.
SB17 Open Short to bypass the 5V domain for the nPM1300 PMIC.
SB18 Closed Cut to disconnect VSYS from P5V0.
SB19 Open Short to connect VDD:nRF and VDD:IO.
SB20 Open Short to disconnect VDD:_nRF_PMIC and VDD:IO.
SB21 Open Short to connect VOUT2 and VDD:IO.
SB22 Open Short to enable the 100 kΩ pull up resistor for the RESET_BUTTON signal
SB23 Closed Cut to disconnect the VDD:IO domain from external flash power.
SB24 Open Short to connect the VDD:nRF domain for supplying power to the external flash.
SB25 Open Short to connect RESET button to the nRF54_RESET.
SB26 Closed Cut to disconnect debugger from the RESET button line.
SB27 Open Short to use VDD:nRF_PMIC as the source for LDO1.
SB28 Closed Cut to disconnect P5V0 as the source for LDO1.
SB29 Closed Cut to disconnect P5V0 as the source for LDO2.
SB30 Open Short to use VDD:nRF_PMIC as the source for LDO2.
SB31 Closed Cut to disconnect VBUS from 5V0:CONN.