This anomaly applies to Revision 1, build codes LACA-A0A.
It was inherited from the previous IC revision Engineering A.
Symptoms
False SEQEND[0] and SEQEND[1] events are being generated.
Conditions
Any of the LOOPSDONE_SEQSTARTn shortcuts are enabled. LOOP register is nonzero and SEQ[1].CNT is set to 1.
Consequences
SEQEND[0] and SEQEND[1] events might falsely trigger other tasks if they are routed through the PPI.
Workaround
Avoid using the LOOPSDONE_SEQSTARTn shortcuts when the LOOP register is nonzero and SEQ[1].CNT is set to 1.