| 7 |
UARTE |
RXD.AMOUNT is not updated after RXFLUSH if FIFO is empty
|
X |
| 8 |
SPIM |
Wrong data is transmitted on MOSI
|
X |
| 20 |
CLOCK |
RADIO payload is not transmitted
|
X |
| 26 |
DPPI |
PPIB between domains uses wrong security attribution
|
X |
| 30 |
CLOCK, GRTC |
GRTC operates incorrectly at low temperature
|
X |
| 37 |
POWER |
Current consumption might increase after pin reset or power cycle
|
X |
| 39 |
CLOCK |
Device can behave erratically after XOSTART
|
X |
| 44 |
EASYDMA |
DMA.RX.AMOUNT is not updated with bytes count after match event
|
X |
| 47 |
POWER |
Device resets while debugging in System OFF mode
|
X |
| 49 |
RADIO |
First bits of on-air packet are not correct
|
X |
| 50 |
RRAMC |
SPU00 incorrectly reports that RRAMC has DMA
|
X |
| 54 |
SPIS |
SDO is configured as an input when SPIS is idle
|
X |
| 59 |
EGU |
EGU uses incorrect security attribution
|
X |
| 63 |
RESET |
Soft reset might not fully reset the device
|
X |
| 69 |
SPIM |
STOPPED event might not be generated in suspend state
|
X |
| 102 |
CCM |
Operation fails when CCM MAC length is set to 0
|
X |
| 104 |
GPIO |
Pins with analog functionality might be shorted together during power-on reset
|
X |
| 105 |
TWIM |
Peripheral becomes unresponsive when disabled during clock stretching
|
X |
| 111 |
SAADC |
Output data is incorrect when noise shaping is used
|
X |
| 114 |
GPIO |
Current consumption increases when Wake on pin is used
|
X |